used. In case of the USB interface, the Smart Label Printer returns a status byte on receipt
of a BULK-IN command from the Host.
The status byte is initialized when the printer is reset (by power-up or command). The
printer sends the status byte, followed by an XON character, and then sets the RTS signal
high. In case of the USB interface, the Smart Label Printer returns a status byte on receipt
of a BULK-IN command from the Host.
4. Printer Buffer Size
The Smart Label Printer’s input buffer has a capacity of 256 bytes.
5. RS-232 Handshaking
When the input buffer is almost full (less than 32 bytes free), the printer will indicate a
buffer full” condition by sending an XOFF character (13h) to the host and setting the
RTS signal low.
After the “buffer full” condition has occurred and the input buffer has been emptied to the
point where there are only 100 bytes of data remaining in the buffer, the printer will
indicate a “buffer empty” condition by sending an XON character (11h) to the host and
setting the RTS signal high.
The buffer full and buffer empty thresholds may be changed with the
CMD_XOFF_THRESH and CMD_XON_THRESH commands, respectively.
6. Serial Interface Cable
The Smart Label Printer may be connected to the host computer using the interface cable
included with the printer. The RS-232 interface cable is wired as follows:
Smart Label Printer Wire PC Host
Signal RJ-11 Color Direction Signal DB-9F
--- 1 Blue
---
--- ---
RD 2 Yellow
!
TD 3
TD 3 Green
"
RD 2
GND 4 Red, shield
#
GND 5, shell
--- 5 Black
---
--- ---
RTS 6 White
"
DSR, CTS 6, 8