The PDL warning appears on the Control Panel, but it
disappears when the next operation is performed.
Consequently, you may not know that the error occurred.
It is recommended that the “ERROR MEMO” of
“DRAWING PARAM.” in the setup menu be turned on, so
that the error message is printed on the drawing.
Note
PDL warning
Description : This message appears if any problem exists in the data
sent from the computer.
Measure : Remove the cause of problem, and recreate the data
correctly. For practical measures, see the table.
Error code Description Measure
2104
I/O error (W) occurred in
the connection to the host
device.
Check the connection of relay units (HUB,
etc.) between host and this device and the
UTP cable, and retry the delivery.
Check that the communication parameters (set
values) are specified correctly in the device.
2000
I/O error (RW) occurred in
the device.
If the device does not recover from this error
by turning the power off and on, take the
following measures.
2001
I/O error (SEL) occurred in
the device.
2002
Memory related error
occurred in the device.
Check if the communication condition and
protocol meet the specifications of the
computer.
Check if the connection cable is defective or
is connected securely.
If the error is not removed, please notify
your dealer or our service center of the
displayed error message and error condition.
2003
Logical error occurred in
the device.
2004
Socket related error
occurred in the device.
2050
Command error occurred in
the device.